Mostrar el registro sencillo del ítem
Design of titanium uncemented femoral stems for hip prosthesis suitable for the Colombian young adult population
dc.contributor.author | López Galiano I.C. | |
dc.contributor.author | Echeverry-Mejía J. | |
dc.contributor.author | Ortiz J.G. | |
dc.contributor.author | Zambrano H.R. | |
dc.contributor.author | Juha M. | |
dc.date.accessioned | 2024-05-02T14:21:19Z | |
dc.date.available | 2024-05-02T14:21:19Z | |
dc.date.issued | 2023 | |
dc.identifier.citation | ) López Galiano, I.C., Echeverry-Mejía, J., Ortiz, J.G., Zambrano, H.R., Juha, M. Design of titanium uncemented femoral stems for hip prosthesis suitable for the Colombian young adult population (2023) Computer Methods in Biomechanics and Biomedical Engineering | es_CO |
dc.identifier.issn | 10255842 | |
dc.identifier.other | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85156275234&doi=10.1080%2f10255842.2023.2205978&partnerID=40&md5=47afc03e32cf55f20b3246a4c8d65e94 | |
dc.identifier.uri | http://hdl.handle.net/10818/59917 | |
dc.description.abstract | The increase of revision surgeries in hip replacement procedure in Colombian young adult population can be addressed by a new design of femoral stem that reduces stress shielding. A new femoral stem was designed using topology optimization as a design aid to reduce the mass in the femoral stem and its overall stiffness, combined with the theoretical, computational, and experimental assessment of the new design that complies with a static and fatigue safety factor greater than one. The new femoral stem design can be used as a design tool to reduce the number of revision surgeries caused by stress shielding. © 2023 Informa UK Limited, trading as Taylor & Francis Group. | en |
dc.format | application/pdf | es_CO |
dc.publisher | Computer Methods in Biomechanics and Biomedical Engineering | es_CO |
dc.relation.ispartofseries | Computer Methods in Biomechanics and Biomedical Engineering | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.source | Universidad de La Sabana | es_CO |
dc.source | Intellectum Repositorio Universidad de La Sabana | es_CO |
dc.subject.other | Axial Fatigue | en |
dc.subject.other | Femoral stem | en |
dc.subject.other | Stress shielding | en |
dc.subject.other | Total hip arthroplasty | en |
dc.title | Design of titanium uncemented femoral stems for hip prosthesis suitable for the Colombian young adult population | en |
dc.type | journal article | es_CO |
dc.type.hasVersion | publishedVersion | es_CO |
dc.rights.accessRights | openAccess | es_CO |
dc.identifier.doi | 10.1080/10255842.2023.2205978 |
Ficheros en el ítem
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a este ítem. |
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Facultad de Ingeniería [506]