Mostrar el registro sencillo del ítem

dc.contributor.authorGiraldo-Cadavid L.F
dc.contributor.authorEcheverry J
dc.contributor.authorVarón-Vega F
dc.contributor.authorBastidas A
dc.contributor.authorRamírez-Jaime A
dc.contributor.authorCardona A.F
dc.contributor.authorLopez Vega C.J
dc.contributor.authorSerrano-Mayorca C.C
dc.contributor.authorGaray D
dc.contributor.authorRincón D.N
dc.contributor.authorOliveros H
dc.contributor.authorRamírez I.A
dc.contributor.authorGarcia-Gallo E
dc.contributor.authorEnciso-Prieto V.A
dc.contributor.authorIbáñez-Prada E.D
dc.contributor.authorCamelo J.C
dc.contributor.authorCucunubo L
dc.contributor.authorBuitrago L
dc.contributor.authorPaipa L.A
dc.contributor.authorLongas L.C
dc.contributor.authorAgudelo-Otálora L.M
dc.contributor.authorPorras Diaz N.F
dc.contributor.authorRachid R.R
dc.contributor.authorHenao I R.D
dc.contributor.authorPedraza S
dc.contributor.authorReyes L.F.
dc.date.accessioned2024-10-09T14:28:42Z
dc.date.available2024-10-09T14:28:42Z
dc.date.issued2024
dc.identifier.issn24058440
dc.identifier.otherhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85192246441&doi=10.1016%2fj.heliyon.2024.e30671&partnerID=40&md5=d5078bbc30820d8774f767be782e21ab
dc.identifier.urihttp://hdl.handle.net/10818/61988
dc.description.abstractBackground: The COVID-19 pandemic in Latin America generated the need to develop low-cost, fast-manufacturing mechanical ventilators. The Universidad de La Sabana and the Fundacion Neumologica Colombiana designed and manufactured the Unisabana-HERONS (USH) ventilator. Here, we present the preclinical and clinical study results to evaluate its effectiveness and safety characteristics in an animal model (Yorkshire Sow) and five patients with acute respiratory failure receiving mechanical ventilatory support for 24 h. Methods: The effectiveness and safety outcomes included maintaining arterial blood gases and pulse oximetry saturation (SpO2), respiratory pressures and volumes (during continuous monitoring) in the range of ARDS and lung-protective strategy goals, and the occurrence of barotrauma. A significance level of 0.05 was used for statistical tests. This clinical trial was registered on Clinicaltrials.gov (NCT04497623) and approved by the ethics committee. Results: Among patients treated with the Unisabana-HERONS, the most frequent causes of acute respiratory failure were pneumonia in 3/5 (60 %) and ARDS in 2/5 (40 %). During the treatment, the ventilatory parameters related to lung protection protocols were kept within the safety range, and vital signs and blood gas were stable. The percentage of time that the respiratory pressures or volumes were out of safety range were plateau pressure >30 cm H2O: 0.00 %; driving pressure >15 cm H2O: 0.06 %; mechanical power >15 J/min: 0.00 %; and Tidal volume >8 mL/kg: 0.00 %. There were no adverse events related to the ventilator. The usability questionnaire retrieved a median score for all items between 9 and 10 (best score: 10), indicating great ease of use. Conclusion: The Unisabana-HERONS ventilator effectively provided adequate gas exchange and maintained the ventilatory parameters in the range of lung protection strategies in humans and an animal model. Furthermore, it is straightforward to use and is a low-cost medical device. © 2024en
dc.formatapplication/pdfes_CO
dc.language.isoenges_CO
dc.publisherHeliyones_CO
dc.relation.ispartofseriesHeliyon Vol. 10 N° 9 art. e30671
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad de La Sabanaes_CO
dc.sourceIntellectum Repositorio Universidad de La Sabanaes_CO
dc.subject.otherCOVID-19en
dc.subject.otherInvasive mechanical ventilatoren
dc.subject.otherRespiratory failureen
dc.titleThe development and implementation of a low-cost mechanical ventilator in a low-middle-income country during the COVID-19 pandemic: The Unisabana-HERONSen
dc.typejournal articlees_CO
dc.type.hasVersionpublishedVersiones_CO
dc.rights.accessRightsopenAccesses_CO
dc.identifier.doi10.1016/j.heliyon.2024.e30671


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 InternationalExcepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International