Mostrar el registro sencillo del ítem

dc.contributor.authorCaballero-Castro L.F
dc.contributor.authorCano-Castaño H.A
dc.contributor.authorMolina-Herrera M
dc.contributor.authorVillalba-Morales J.D
dc.contributor.authorArroyo O.
dc.date.accessioned2024-10-09T14:28:26Z
dc.date.available2024-10-09T14:28:26Z
dc.date.issued2024
dc.identifier.issn23520124
dc.identifier.otherhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85196084916&doi=10.1016%2fj.istruc.2024.106748&partnerID=40&md5=e8dc4161b61ca852426e1f2b94ff0f5d
dc.identifier.urihttp://hdl.handle.net/10818/61948
dc.description.abstractColombia is a country with high seismic activity due to its location at the convergence of the Nazca and South American tectonic plates, making structural safety a key priority in the design, construction, and retrofit of buildings. Currently, one of the most used seismic resistance systems are moment-resisting frames, due to their easy construction and good behavior under vertical loads, however, they are susceptible to structural damage when subjected to moderate to high-intensity earthquakes, which makes the use of seismic protection systems an adequate alternative to prevent damage during seismic events. The Colombian seismic design code NSR-10 proposes a design methodology using a linear structure that represents a non-linear behavior of the building when the expected design earthquake occurs through the response modification factor R. However, the NSR-10 seismic design code does not contemplate the response modification factor for structures with seismic protection systems. Therefore, in this research, a design procedure was configured for buildings with moment-resisting frames of reinforced concrete and steel equipped with TADAS (triangular-plate added damping and stiffness) dampers. The procedure evaluated the developed response modification factor of structures located in high seismic hazard areas in Colombia and considered regular buildings with varying numbers of stories and special energy dissipation capacity. The capacity of the structures was evaluated through nonlinear static analysis using the Pushover method in SAP2000 software. Finally, the response modification factors were calculated for regular buildings with moment-resisting frames and different numbers of stories. © 2024 Institution of Structural Engineersen
dc.formatapplication/pdfes_CO
dc.language.isoenges_CO
dc.publisherStructureses_CO
dc.relation.ispartofseriesStructures Vol. 65 N° art. 106748
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad de La Sabanaes_CO
dc.sourceIntellectum Repositorio Universidad de La Sabanaes_CO
dc.subject.otherMoment resisting framesen
dc.subject.otherNonlinear static analysisen
dc.subject.otherResponse modification factoren
dc.subject.otherSeismic response controlen
dc.subject.otherTADAS damperen
dc.titleEvaluating the response modification factor (R) for reinforced concrete and steel structures equipped with TADAS devices designed for high seismic hazard in Colombiaen
dc.typejournal articlees_CO
dc.type.hasVersionpublishedVersiones_CO
dc.rights.accessRightsopenAccesses_CO
dc.identifier.doi10.1016/j.istruc.2024.106748


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 InternationalExcepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International