Mostrar el registro sencillo del ítem

dc.contributor.advisorDíaz Quijano, Diana Marcela
dc.contributor.authorLópez Osorio, Gildardo Mauricio
dc.date.accessioned2017-11-16T14:53:20Z
dc.date.available2017-11-16T14:53:20Z
dc.date.created2017
dc.date.issued2017-11-16
dc.identifier.citationEpstein SK. Extubation. Respir Care [Internet]. 2002 Apr [cited 2014 Aug 19];47(4):483–92; discussion 493–5. Available from: http://www.ncbi.nlm.nih.gov/pubmed/11929619
dc.identifier.citationYang KL, Tobin MJ. A prospective study of indexes predicting the outcome of trials of weaning from
dc.identifier.citationmechanical ventilation. N Engl J Med [Internet]. 1991 May 23 [cited 2014 Sep 27];324(21):1445–50. Available from: http://www.ncbi.nlm.nih.gov/pubmed/2023603
dc.identifier.citationPetrof BJ, Jaber S, Matecki S. Ventilator-induced diaphragmatic dysfunction. Curr Opin Crit Care [Internet]. 2010 Feb [cited 2014 Aug 18];16(1):19–25. Available from: http://www.ncbi.nlm.nih.gov/pubmed/19935062
dc.identifier.citationMatamis D, Soilemezi E, Tsagourias M, Akoumianaki E, Dimassi S, Boroli F, et al. Sonographic evaluation of the diaphragm in critically ill patients. Technique and clinical applications. Intensive Care Med [Internet]. 2013 May [cited 2014 Jul 16];39(5):801–10. Available from: http://www.ncbi.nlm.nih.gov/pubmed/23344830
dc.identifier.citationDysfunction of the Diaphragm — NEJM [Internet]. [cited 2014 Aug 18]. Available from: http://www.nejm.org/doi/full/10.1056/NEJMra1007236
dc.identifier.citationVassilakopoulos T, Petrof BJ. Ventilator-induced diaphragmatic dysfunction. Am J Respir Crit Care Med [Internet]. 2004 Feb 1 [cited 2014 Aug 18];169(3):336–41. Available from: http://www.ncbi.nlm.nih.gov/pubmed/14739134
dc.identifier.citationRapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated Humans — NEJM [Internet]. [cited 2014 Aug 18]. Available from: http://www.nejm.org/doi/full/10.1056/NEJMoa070447. 8. Effect of Mechanical Ventilation on the Diaphragm — NEJM [Internet]. [cited 2014 Aug 18]. Available from: http://www.nejm.org/doi/full/10.1056/NEJMe0801226.
dc.identifier.citationDaniel Martin A, Smith BK, Gabrielli A. Mechanical ventilation, diaphragm weakness and weaning: a rehabilitation perspective. Respir Physiol Neurobiol [Internet]. 2013 Nov 1 [cited 2014 Jul 10];189(2):377–83. Available from: http://www.ncbi.nlm.nih.gov/pubmed/23692928
dc.identifier.citationVivier E, Mekontso Dessap A, Dimassi S, Vargas F, Lyazidi A, Thille AW, et al. Diaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation. Intensive Care Med [Internet]. 2012 May [cited 2014 Aug 12];38(5):796–803. Available from: http://www.ncbi.nlm.nih.gov/pubmed/22476448
dc.identifier.citationDiNino E, Gartman EJ, Sethi JM, McCool FD. Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation. Thorax [Internet]. 2014 May [cited 2014 Jul 30];69(5):423–7. Available from: http://www.ncbi.nlm.nih.gov/pubmed/24365607.
dc.identifier.citationKim WY, Suh HJ, Hong S-B, Koh Y, Lim C-M. Diaphragm dysfunction assessed by ultrasonography: influence on weaning from mechanical ventilation. Crit Care Med [Internet]. 2011 Dec [cited 2014 Aug 7];39(12):2627–30. Available from: http://www.ncbi.nlm.nih.gov/pubmed/21705883.
dc.identifier.citationJiang J-R, Tsai T-H, Jerng J-S, Yu C-J, Wu H-D, Yang P-C. Ultrasonographic evaluation of liver/spleen movements and extubation outcome. Chest [Internet]. 2004 Jul [cited 2014 Aug 19];126(1):179–85. Available from: http://www.ncbi.nlm.nih.gov/pubmed/15249460.
dc.identifier.citationVassilakopoulos T, Zakynthinos S. The tension - time index and the frequency / tidal volumen ratio are the major pathophysiologic determinants of weaning failure and success. Am J Respir Crit Care Med. 1998: 158 (2): 378 - 85.
dc.identifier.citationVassilakopoulos T, Petrof BJ. Ventilator - induced diaphragmatic dysfunction. Am J Respir Crit Care Med. 2004: 169 (3): 336 - 41.
dc.identifier.citationLaghi F, Cattapan SE, Jubran A, et al. Is weaning failure caused by low - frecuency fatigue of the diaphram? Am J Resp Crit Care Med. 2003: 167 (2);120-7.
dc.identifier.citationDreem S. Acquired neuromuscular disorders in the intensive care unit. In: Thoracic trauma and critical care. Springer; 2002:529 - 534. Accessed 5/13/2014 3:07;11 AM.
dc.identifier.citationAnzureto A, Peters JI, Tobin Mj, et al. Effects of prolonged controlled mechanical ventilation on diapghragmatic function in healthy adult baboons. Crit Care Med. 1997;28(3):358-54.
dc.identifier.citationBellemare F, Grassino A. Force reserve of the diaphragm in patient with chronic obstructive pulmonary disease. J Appl Physiol Respir Environ Exerc Physiol. 1983; 55(1 Pt1) 8-15.
dc.identifier.citationShanely RA, Zergeroglu MA, Lennon SL, et al. Mechanical ventilation çinduced diaphragmatic atrophy is associated with oxidative injury and increased proteolytic activity. Am J Resp Crit Care Med. 2002; 166 (10):1369 - 74.
dc.identifier.citationFerrari Giovanni, De Filippi. Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation. Critical Ultrasound Journal 2014, 6:8.
dc.identifier.citationRamirez-Sarmiento A, Orozco-Levi M, Barreiro E, Mendez R, Ferrer A, Broquetas J, et al. Expiratory muscle endurance in chronic obstructive pulmonary disease. Thorax. 2002;57:132–6.
dc.identifier.citationSinderby C, Beck J, Spahija J, Weinberg J, Grassino A. Voluntary activation of the human diaphragm in health and disease. J Appl Physiol. 1998;85:2146–58.
dc.identifier.citationMoxham JR, Edwards RH, Aubier M, De Troyer A, Farkas G, Macklem PT, et al. Changes in the EMG power spectrum (high_to_low ratio) with forced fatigue n humans. J Appl Physiol. 1982;53:1094–9.
dc.identifier.citationTom Schepens, Walter V. Schepens et al. The course of diaphragm atrophy in ventilated patients assessed with ultrasound: a longitudinal cohort study; Critical Care (2015) 19:422.
dc.identifier.citationM. Umbrello, P. Formenti, et al. Diaphragm ultrasound as indicator of respiratory effort in critically ill patients undergoing assisted mechanical ventilation: a pilot clinical study. 2014, 6:8 (21).
dc.identifier.citationEpsteinSK. Weaning, Respir Care Clin North Am [Internet] 2000;6(2):253-301) [cited2014 Aug 18]; Available from:https://www.ncbi.nlm.nih.gov/pubmed/10757963
dc.identifier.citationMeade MO , Guayatt GH, Cook Dj. Weaning from mechanical ventilation: the evidence from clinical research. Respir Care 2001;46(12):1408-15
dc.identifier.citationNeil R. MacIntyre. Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support : A Collective Task Force Facilitated by the American College of Chest Physicians; the American Association for Respiratory Care; and the American College of Critical Care Medicine. Chest 2001;120 (6 suppl) : 375s - 848s
dc.identifier.citationWilliam m. coplin , david j. pierson , kathy d. cooley. Implications of Extubation Delay in Brain-Injured Patients Meeting Standard Weaning Criteria. AJRCCM 2000;161:1530-6
dc.identifier.urihttp://hdl.handle.net/10818/31979
dc.description15 Páginas.es_CO
dc.description.abstractIntroduccion: El 20% de los pacientes críticos tienen un proceso de retiro difícil de la Ventilación Mecánica (VM) describiendose la disfunción diafragmática como una de las principales causas de este proceso. El ultrasonido es una técnica no invasiva útil para evaluar y diagnósticar las alteraciones diafragmáticas. Objetivo: Determinar las medidas ecográficas que permitan establecer la presencia de disfunción diafragmática y que puedan ser predictoras de fracaso en el retiro de la VM. Materiales y metodos: Estudio de pruebas diagnósticas en pacientes con más de 48 horas en VM en quienes inicia el proceso de retiro de la ventilación, previo al desarrollo de la prueba de respiración espontánea se realizó la ecografía diafragmática. Se incluyeron variables clínicas, mediciones de ecografía y desenlaces. La estadística fue descriptiva e inferencial calculando sensibilidad, especificidad, valor predictivo positivo y negativo y construyendo una curva ROC. Resultados: Fueron incluidos 97 pacientes sometidos al proceso de retiro de la VM. La edad promedio fue 58 años, La principal causa de intubación fue la falla respiratoria hipoxémica (63%)., el tiempo de VM previo al retiro fue 4 días y el tiempo del proceso de retiro del ventilador fueron 2 días en promedio. Los pacientes que fracasarón en el retiro del ventilador presentarón mayor tiempo en VM y estancia en la UCI (5 Vs 7 días, p 0.026 y 10 Vs 14 días, p 0.032). El fracaso se presentó en el 21% de los casos y la disfunción diafragmática fue observada en el 10% de ellos. Los hallazgos ecográficos en quienes fracasaron fueron el menor desplazamiento del diafragma, mayor tiempo inspiratorio con menor velocidad de contracción del músculo, siendo esta última significativa (2.9 Vs 1.77cm/seg, p <0.001).es_CO
dc.language.isospaes_CO
dc.publisherUniversidad de La Sabanaes_CO
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceUniversidad de La Sabana
dc.sourceIntellectum Repositorio Universidad de La Sabana
dc.subjectRespiración artificial
dc.subjectUltrasonido
dc.subjectAtención al enfermo
dc.subjectDiagnóstico
dc.titleEcografía del diafragma y destete ventilatorioes_CO
dc.typebachelorThesises_CO
dc.publisher.programEspecialización en Neumología
dc.publisher.departmentFacultad de Medicina
dc.identifier.local267048
dc.identifier.localTE09374
dc.type.localTesis de especialización
dc.type.hasVersionpublishedVersion
dc.rights.accessRightsrestrictedAccess
dc.creator.degreeEspecialista en Neumología


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 InternationalExcepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 International