Mostrar el registro sencillo del ítem

dc.contributor.advisorBuitrago Bernal, Ricardo Antonio
dc.contributor.advisorPoveda, Claudia Marcela
dc.contributor.authorCabrales Pinzón, Estefanía
dc.contributor.authorDíaz Reyes, René Ricardo
dc.date.accessioned2013-12-09T14:32:14Z
dc.date.available2013-12-09T14:32:14Z
dc.date.created2013
dc.date.issued2013-12-09
dc.identifier.citationKarakitsos D. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Critical Care. 2006; 10(6):R162.
dc.identifier.citation. Domino K, Bowdle. Injuries and liability related to central vascular catheters: a close claimed analysis. Anesthesiology. 2004; 100: 1411 – 1418.
dc.identifier.citationRuesch, Walder. Complications of central venous catheters: internal jugular versus subclavian access: A systematic review. Critical Care Medicine. 2002; 30: 454 – 460
dc.identifier.citationRandolph AG, Cook DJ, Gonzales CA. Ultrasound Guidance for Placement of Central Venous Catheters: A Meta-analysis of the Literature. Critical Care Medicine 1996; 24(12): 2053-8
dc.identifier.citationMaecken, Grau. Ultrasound imaging in vascular access. Critical Care Medicine. 2007; 35: S178 – S185.
dc.identifier.citationLegler. Doppler localization of the internal jugular vein facilitates central venous cannulation. Anesthesiology. 1984; 60:481 -482.
dc.identifier.citationSubodh Satyarthy, Harpreet Singh Minhas The success rate and safety of internal jugular vein cannulation using anatomical landmark technique in patients undergoing cardiothoracic surgery. Annals of cardiac anesthesia. Vol. 16: 16 – 19. 2013.
dc.identifier.citationMarie Pauline. Accidental Carotid Artery Catheterization During Attempted Central Venous Catheter Placement: A Case Report. AANA Journal. 2012.
dc.identifier.citationBailey PL, Glance LG, Eaton MP, Parshall B, McIntosh S. A survey of the use of ultrasound during central venous catheterization. Anesthesia Analgesia 2007; 104:491–7
dc.identifier.citationPeris, Implantation of 3951 Long-Term Central Venous Catheters: Performances, Risk Analysis, and Patient Comfort After Ultrasound-Guidance Introduction. Anesthesia – analgesia; 2010; Vol 111, No.5; 1194 – 1201
dc.identifier.citationDíaz, Sanabria. Algoritmo de práctica clínica basado en la evidencia para el uso de ultrasonido en la colocación de catéteres centrales. Revista colombiana de Anestesiología. 2005; 33: 51- 58
dc.identifier.citationTowlani, Ashita. Continuous Renal-Replacement Therapy for Acute Kidney Injury. New England Journal of Medicine. 2012; 367: 2505 – 2514.
dc.identifier.citationGordon, Saliken. US guided puncture of the internal jugular vein: complications and anatomical considerations. Journal Vascular Interventional Radiology. 1998; 9: 336 – 338.
dc.identifier.citationDenis. Anatomical variations of the internal jugular vein location: Impact on central venous access. Critical Care Medicine. 1991; 19: 1516 – 1519.
dc.identifier.citationMaecken. Relationship of the internal jugular vein to the common carotid artery: Implications for ultrasound-guided vascular access. European Journal of Anesthesiology. 2011; 28: 351– 355.
dc.identifier.citationSlama M. Improvement of internal jugular vein cannulation using an ultrasoundguided technique. Intensive Care Medicine. 1997 Aug; 23(8):916-9.
dc.identifier.citationBolliger CT. Clinical Chest Ultrasound, from the ICU to the bronchoscopy suite. 2009; Chapter 8: 69 – 76.
dc.identifier.urihttp://hdl.handle.net/10818/9021
dc.description46 Páginas.
dc.description.abstractLa colocación de dispositivos intravasculares es uno de los procedimientos invasivos más frecuentemente realizados en la Unidad de Cuidado Intensivo, siendo la técnica de inserción a ciegas la más usada y a su vez la que se asocia con un mayor número de complicaciones mecánicas inmediatas. Con el empleo del ultrasonido como herramienta de apoyo diagnóstico y terapéutico a la cabecera del paciente se ha descrito en varias publicaciones la superioridad de su uso durante la colocación de catéteres centrales en salas de cirugía, emergencias y pacientes críticamente enfermos, siendo este último grupo considerado de alto riesgo para este tipo de procedimiento basado en la presencia de múltiples factores que se asocian a una mayor dificultad técnica para obtener el acceso vascular. La presencia de variantes anatómicas de la yugular interna (VYI) con respecto a la carótida (AC) podría estar asociada a mayores complicaciones mecánicas no encontrándose a la fecha reportes de esta asociación en la literatura.es_CO
dc.language.isospaes_CO
dc.publisherUniversidad de la Sabana
dc.sourceUniversidad de La Sabana
dc.sourceIntellectum Repositorio Universidad de La Sabana
dc.subjectArterias -- Carotidas
dc.subjectSangre -- Circulación
dc.subjectAtención médica crítica -- Cuidados críticos (Medicina) -- Colombia
dc.titleVariantes anatómicas de la yugular interna con respecto a la carótida común y su asociación con complicaciones mecánicas en el acceso venoso central guiado por ultrasonografia en pacientes de cuidado intensivoes_CO
dc.typebachelorThesis
dc.publisher.programEspecialización en Medicina Crítica y Cuidado Intensivo
dc.publisher.departmentFacultad de Medicina
dc.identifier.local255641
dc.identifier.localTE06031
dc.type.localTesis de especialización
dc.type.hasVersionpublishedVersion
dc.rights.accessRightsopenAccess
dc.creator.degreeEspecialista en Medicina Crítica y Cuidado Intensivo


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem