Inferior approach instead of standard “pull-down” technique for transseptal puncture in difficult anatomy
Abordaje inferior en lugar de la técnica estándar "pull-down" para la punción transeptal en anatomía difícil
Enlaces del Item
URI: http://hdl.handle.net/10818/62643Visitar enlace: https://www.scopus.com/inward/ ...
ISSN: 1383875X
DOI: 10.1007/s10840-020-00750-w
Compartir
Estadísticas
Ver Estadísticas de usoCatalogación bibliográfica
Mostrar el registro completo del ítemFecha
2020Resumen
A 71-year-old male with kyphoscoliosis (Fig. 1a), persistent atrial fibrillation recurrent to amiodarone, LVEF 35%, and suspicious of tachycardiomyopathy was admitted for pulmonary veins isolation. An Agilis NxT Steerable introducer (St Jude Medical, Minnetonka, MN, USA) and an intracardiac echo (ICE) probe were advanced into the superior vena cava and right atrium,
respectively. Un hombre de 71 años con cifoescoliosis (Fig. 1a), fibrilación auricular persistente recurrente a amiodarona, FEVI del 35% y sospecha de taquicardiomiopatía fue ingresado para aislamiento de venas pulmonares. Un introductor orientable Agilis NxT (St Jude Medical, Minnetonka, MN, EE. UU.) y se hizo avanzar una sonda de eco intracardíaco (ICE) hacia la vena cava superior y la aurícula derecha.