Mostrar el registro sencillo del ítem
Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study
dc.contributor.author | Giraldo Cadavid, Luis Fernando | |
dc.contributor.author | Bastidas Goyes, Alirio Rodrigo | |
dc.contributor.author | Padilla-Ortiz, Diana Marcela | |
dc.contributor.author | Concha Galan, Diana Carolina | |
dc.contributor.author | Bazurto Zapata, María Angélica | |
dc.contributor.author | Vargas, Leslie | |
dc.date.accessioned | 4/24/2018 11:38 | |
dc.date.available | 2018-04-24T16:38:21Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | Giraldo-Cadavid LF, Bastidas AR, Padilla-Ortiz DM, et al Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study BMJ Open 2017;7:e015235. doi: 10.1136/bmjopen-2016-015235 | es_CO |
dc.identifier.other | http://bmjopen.bmj.com/content/7/8/e015235.long | |
dc.identifier.uri | http://hdl.handle.net/10818/32834 | |
dc.description | 9 páginas | es_CO |
dc.description.abstract | Patients with obstructive sleep apnoea hypopnoea syndrome (OSA) might have varying degrees of laryngopharyngeal mechanical hyposensitivity that might impair the brain’s capacity to prevent airway collapse during sleep. However, this knowledge about sensory compromises in OSA comes from studies performed using methods with little evidence of their validity. Hence, the purpose of this study is to assess the reliability and accuracy of the measurement of laryngopharyngeal mechanosensitivity in patients with OSA using a recently developed laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER). | en |
dc.format | application/pdf | es_CO |
dc.language.iso | eng | es_CO |
dc.publisher | BMJ : British Medical Journal | es_CO |
dc.relation.ispartofseries | BMJ Open 2017; 7: e015235 | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.source | Universidad de La Sabana | es_CO |
dc.source | Intellectum Repositorio Universidad de La Sabana | es_CO |
dc.title | Accuracy and reliability of the sensory test performed using the laryngopharyngeal endoscopic esthesiometer and rangefinder in patients with suspected obstructive sleep apnoea hypopnoea: protocol for a prospective double-blinded, randomised, exploratory study | es_CO |
dc.title.alternative | Exactitud y fiabilidad de la prueba sensorial realizada con el estetoscopio endoscópico laringofaríngeo y el telémetro en pacientes con sospecha de apnea obstructiva del sueño hipopnea: protocolo para un estudio prospectivo, doble ciego, aleatorizado, exploratorio | es_CO |
dc.type | article | en |
dc.type.hasVersion | publishedVersion | es_CO |
dc.rights.accessRights | openAccess | es_CO |
dc.identifier.doi | 10.1136/bmjopen-2016-015235 |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Facultad de Medicina [1331]