Mostrar el registro sencillo del ítem
Valores de referencia de oscilometría de impulso en niños de 3 a 5 años en la ciudad de Bogotá
dc.contributor.advisor | Díaz Quijano, Diana Marcela | |
dc.contributor.advisor | Dueñas, Elida | |
dc.contributor.advisor | Granados, Carlos Eduardo | |
dc.contributor.author | López Barón, Eliana | |
dc.contributor.author | Morales Jiménez, Juan Carlos | |
dc.date.accessioned | 2015-07-08T15:59:14Z | |
dc.date.available | 2015-07-08T15:59:14Z | |
dc.date.created | 2015 | |
dc.date.issued | 2015-07-08 | |
dc.identifier.citation | Al-Mutairi SS, Sharma PN, Al-Alawi a, Al-Deen JS. Impulse oscillometry: an alternative modality to the conventional pulmonary function test to categorise obstructive pulmonary disorders. Clin Exp Med [Internet]. 2007 Jun [cited 2012 Jul 14];7(2):56–64. Available from: http://www.ncbi.nlm.nih.gov/pubmed/17609877 | |
dc.identifier.citation | Komarow HD, Myles IA, Uzzaman A, Metcalfe DD. Impulse oscillometry in the evaluation of diseases of the airways in children. Ann Allergy, Asthma Immunol [Internet]. 2011;106(3):191–9. Available from: http://www.sciencedirect.com.ezproxy.unisabana.edu.co/science/article/pii/S108112 0610010653 | |
dc.identifier.citation | Rodolfo K, Peirano M. Oscilometría de impulso (IOS) en niños. Rev Neumol Pediátrica Soc Chil neumolo´gia pediátrica [Internet]. 2010;5(2):89–95. Available from: www.neumologia-pediatrica.cl | |
dc.identifier.citation | Frei J, Jutla J, Kramer G, Hatzakis GE, Ducharme FM, Davis GM. Impulse oscillometry: reference values in children 100 to 150 cm in height and 3 to 10 years of age. Chest [Internet]. 2005 Sep;128(3):1266–73. Available from: http://www.ncbi.nlm.nih.gov/pubmed/16162717 | |
dc.identifier.citation | Smith HJ, Reinhold P, Goldman MD. Chapter 5. Forced oscillation technique and impulse oscillometry. Eur Respir Monogr [Internet]. 2005;(31):72–105. Available from: http://erm.ersjournals.com/content/ermlft/1/SEC7.body | |
dc.identifier.citation | Komarow HD, Skinner J, Young M, Gaskins D, Nelson C, Gergen PJ, et al. A study of the use of impulse oscillometry in the evaluation of children with asthma: analysis of lung parameters, order effect, and utility compared with spirometry. Pediatr Pulmonol [Internet]. 2012 Jan [cited 2012 Jul 14];47(1):18–26. Available from: http://www.ncbi.nlm.nih.gov/pubmed/22170806 | |
dc.identifier.citation | Garcia E, Aristizabal G, Vasquez C, Rodriguez-Martinez CE, Sarmiento OL, Satizabal CL. Prevalence of and factors associated with current asthma symptoms in school children aged 6-7 and 13-14 yr old in Bogotá, Colombia. Pediatr Allergy Immunol [Internet]. 2008 Jun [cited 2013 Jun 26];19(4):307–14. Available from: http://www.ncbi.nlm.nih.gov/pubmed/18208464 | |
dc.identifier.citation | Dennis R, Caraballo L, García E, Rojas MX, Rondón M a, Pérez A, et al. Prevalence of asthma and other allergic conditions in Colombia 2009-2010: a crosssectional study. BMC Pulm Med [Internet]. BioMed Central Ltd; 2012 May 2 [cited 2012 Jul 14];12(1):17. Available from: http://www.ncbi.nlm.nih.gov/pubmed/22551171 | |
dc.identifier.citation | Malmberg LP, Pelkonen a, Poussa T, Pohianpalo a, Haahtela T, Turpeinen M. Determinants of respiratory system input impedance and bronchodilator response in healthy Finnish preschool children. Clin Physiol Funct Imaging. 2002;22:64–71. | |
dc.identifier.citation | Proceedings and recommendations of the GAP conference Committee cystic fibrosis foundation, Taussig LM, Chernick V, Wood R, Farrell P MR. Standardization of lung function testing in children. J Pediatr. 1980;97(4):668–76. | |
dc.identifier.citation | Rosenfeld M, Allen J, Arets BHGM, Aurora P, Beydon N, Calogero C, et al. An Official American Thoracic Society Workshop Report: Optimal Lung Function Tests for Monitoring Cystic Fibrosis, Bronchopulmonary Dysplasia, and Recurrent Wheezing in Children Less Than 6 Years of Age. Ann Am Thorac Soc [Internet]. American Thoracic Society - AJRCCM; 2013 Apr 1;10(2):S1–11. Available from: http://www.atsjournals.org/doi/abs/10.1513/AnnalsATS.201301-017ST | |
dc.identifier.citation | Beydon N, Davis SD, Lombardi E, Allen JL, Arets HGM, Aurora P, et al. An official American Thoracic Society/European Respiratory Society statement: pulmonary function testing in preschool children. Am J Respir Crit Care Med [Internet]. 2007 Jun 15 [cited 2012 Jul 14];175(12):1304–45. Available from: http://www.ncbi.nlm.nih.gov/pubmed/17545458 | |
dc.identifier.citation | Oostveen E, MacLeod D, Lorino H, Farre R, Hantos Z, Desager K, et al. The forced oscillation technique in clinical practice: methodology, recommendations and future developments. Eur Respir J [Internet]. 2003 Dec 1 [cited 2012 Jul 14];22(6):1026– 41. Available from: http://erj.ersjournals.com/cgi/doi/10.1183/09031936.03.00089403 | |
dc.identifier.citation | Park JH, Yoon JW, Shin YH, Jee HM, Wee YS, Chang SJ, et al. Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children. Korean J Pediatr [Internet]. 2011 Feb [cited 2012 Jul 14];54(2):64–8. Available from: http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=3077503&tool=pmcentrez &rendertype=abstract | |
dc.identifier.citation | Nowowiejska B, Tomalak W, Radliński J, Siergiejko G, Latawiec W, Kaczmarski M. Transient reference values for impulse oscillometry for children aged 3-18 years. Pediatr Pulmonol. 2008;43(November):1193–7. | |
dc.identifier.citation | Gochicoa-rangel L, Torre-bouscoulet L, Martínez-bricen D, Rodríguez-moreno L, Cantu G. Values of Impulse Oscillometry in Healthy Mexican Children and Adolescents. 2015;(C):1–9. | |
dc.identifier.citation | Hellinckx J, De Boeck K, Bande-Knops J, Van der Poel M, Demedts M. Bronchodilator response in 3-6.5 years old healthy and stable asthmatic children. Eur Respir J. 1998;12:438–43. | |
dc.identifier.citation | Dencker M, Malmberg LP, Valind S, Thorsson O, Karlsson MK, Pelkonen a, et al. Reference values for respiratory system impedance by using impulse oscillometry in children aged 2-11 years. Clin Physiol Funct Imaging [Internet]. 2006 Jul;26(4):247– 50. Available from: http://www.ncbi.nlm.nih.gov/pubmed/16836699 | |
dc.identifier.citation | Lee J-Y, Seo J-H, Kim HY, Jung YH, Kwon J-W, Kim B-J, et al. Reference Values of Impulse Oscillometry and Its Utility in the Diagnosis of Asthma in Young Korean Children. J Asthma. 2012;49(8):811–6. | |
dc.identifier.uri | http://hdl.handle.net/10818/16840 | |
dc.description | 16 Páginas. | |
dc.description.abstract | Introducción. La oscilometría de impulso (IOS) prueba que mide la resistencia y reactancia de la vía aérea es una herramienta útil para el diagnóstico y tratamiento de la enfermedad respiratoria y no requiere maniobras respiratorias forzadas, se requieren valores de referencia para cada grupo poblacional dependiendo de las características locales. Objetivo. Determinar los valores de referencia normales de la IOS en niños pre-escolares en Bogotá en la prueba pre y post broncodilatador y establecer sus ecuaciones de referencia Métodos. Se realizó un estudio de corte transversal se incluyeron niños pre-escolares sin enfermedad respiratoria que asistían a jardines infantiles de la ciudad de Bogotá entre noviembre de 2013 y noviembre de 2014. A estos niños se les aplicó un cuestionario de enfermedad respiratoria modificado y se seleccionaron 96 niños aptos para realizar la prueba según criterios para estudios de valores normales de la ATS/ERS. Resultado. La variable independiente más influyente en los valores de parámetros de IOS fue la talla, con una disminución de R5 y R20 al aumentar la talla y un ascenso de X5 al aumentar la talla. Conclusiones. Se determinaron los valores de referencia normales para niños de 3 a 5 años sanos de Bogotá para la oscilometría de impulso antes y después de la aplicación de 400mcg de salbutamol. Los valores que fueron estadísticamente significativos al correlacionarse con la talla fueron las variables R5, R20 y X5. | es_CO |
dc.language.iso | spa | es_CO |
dc.publisher | Universidad de La Sabana | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.source | Universidad de La Sabana | |
dc.source | Intellectum Repositorio Universidad de La Sabana | |
dc.subject | Aparato respiratorio | |
dc.subject | Oscilometría de impulsos -- Bogotá, Colombia | |
dc.subject | Pruebas de función respiratoria | |
dc.title | Valores de referencia de oscilometría de impulso en niños de 3 a 5 años en la ciudad de Bogotá | es_CO |
dc.title.alternative | Impulse oscilometry. Referece values in children 3 to 5 years of age in Bogotá, Colombia | |
dc.type | bachelorThesis | es_CO |
dc.publisher.program | Especialización en Pediatría | es_CO |
dc.publisher.department | Facultad de Medicina | es_CO |
dc.identifier.local | 260231 | |
dc.identifier.local | TE07180 | |
dc.type.local | Tesis de especialización | |
dc.type.hasVersion | publishedVersion | |
dc.rights.accessRights | openAccess | es_CO |
dc.creator.degree | Especialización en Pediatría |