@misc{10818/60108, year = {2021}, url = {http://hdl.handle.net/10818/60108}, abstract = {Aim: The present study sought to compare the clinical outcomes between four operative techniques for laparoscopic appendectomy in a Colombian institution, following the adoption of reuse and reprocessing policies for medical devices in the Region of Americas (2014). Materials and Methods: One-way analysis of variance (ANOVA) and Kruskal Wallis tests were used to compare the rates of Surgical Site Infection (SSI), unplanned reoperation, readmission and mortality (confined to 30 days after surgery) of these operative techniques: Technique 1: Ligature of appendiceal stump with endo stitch plus mesenteric dissection with conventional bipolar electrocoagulation; Technique 2: Clipping of stump with polymer endoclip plus mesenteric dissection with conventional bipolar electrocoagulation; Technique 3: Clipping of stump with polymer endoclip plus mesenteric dissection with monopolar electrocoagulation; Technique 4: Clipping of stump plus mesenteric dissection with polymer endoclip. Results: A total of 551 patients were included. No differences were found in the demographic characteristics of the patients between techniques during ANOVAs. The global outcomes were SSI (5.44%), unplanned reoperation (3.08%), readmission (15.97%) and mortality (0.18%). Significant differences were found (p < 0.05) in these outcomes explained by higher rates of SSI and unplanned reoperation with Technique 1. Conclusions: The overall outcomes of laparoscopic appendectomy, after the adoption of policies for the reuse and reprocessing of medical devices, are similar to those accepted globally when using operative techniques 2-3-4 in equivalent populations of patients with acute appendicitis. In this context, our results invite to use with caution technique-1. © 2021, Sociedad de Cirujanos de Chile. All rights reserved.}, publisher = {Revista de Cirugia}, title = {Comparison of clinical outcomes with four laparoscopic appendectomy techniques after implementation of medical devices reuse policy}, title = {Comparación de los desenlaces clínicos con cuatro técnicas de apendicetomía laparoscópica tras la implementación de políticas de reúso de dispositivos médicos}, doi = {10.35687/s2452-45492021002598}, author = {Vergara Ó.A. and Domínguez L.C. and Sierra D.O. and Gamboa Ó.A. and Segnini F.J.}, }