@article{10818/13180, year = {2007}, month = {1}, url = {http://hdl.handle.net/10818/13180}, abstract = {El objetivo del presente estudio fue determinar, mediante una investigación metodológica, la validez facial y la confiabilidad (consistencia interna y estabilidad) de la versión en español del instrumento Escala de Medición del Proceso de Afrontamiento y Adaptación (ESCAPS) de Callista Roy, con el fin de evaluar su comportamiento y dominio. La escala, denominada en inglés Coping Adaptation Processing Scale (CAPS), fue diseñada por Callista Roy en el año 2004 (1), con el fin de identificar las estrategias de afrontamiento y adaptación que la persona utiliza para hacer frente a situaciones difíciles o críticas. Está integrada por 47 ítems agrupados en cinco factores, con una calificación Likert de cuatro puntos Para establecer la validez facial se utilizaron dos métodos; el primero correspondió a un panel de expertos, quienes evaluaron el instrumento considerando tres criterios de calificación: claridad, precisión, comprensión; al respecto se encontró que 45 (96%) del total de los 47 ítems del instrumento cumplieron estos criterios. El segundo correspondió a cinco sujetos de estudio quienes evaluaron el instrumento en su totalidad, determinando su comprensión. De esta forma se estableció que el instrumento aparenta tener validez facial. Para establecer la confiabilidad del instrumento, éste se aplicó a una muestra de 417 sujetos mayores de cincuenta años, con una función mental intacta, procedentes del municipio de Chía y la ciudad de Bogotá, durante el periodo comprendido entre agosto de 2005 a marzo de 2006, quienes fueron escogidos mediante un muestreo aleatorio por conveniencia. La confiabilidad se evaluó a través de la consistencia interna, con un Alta de Cronbach de 0,88, y la estabilidad se midió a través del coeficiente de correlación de Spearman (r = 0,94) para el total del instrumento y un Anova con un valor de probabilidad (p=NS) estadísticamente no significativo, confirmando la estabilidad de los puntajes obtenidos a través del tiempo.Los resultados confirman la validez facial y la confiabilidad de la Escala de Medición de Proceso de Afrontamiento y adaptación de Callista Roy, en su versión en español.}, abstract = {The purpose of the study was to determine, by means of a methodological research, the face validity as well as the rehability level (internal consistency reliability and stability) of the Spanish version instrument of the Coping Adaptation Processing Scale of Callista Roy (ESCAPS, for its Spanish name), in order to evaluate its behavior and domain. The scale was designed by Callista Roy in the year 2004 (1) for identifying, coping and adapting strategies used by an individual to to cope with difficult or critical events. It consists of 47 items set into 5 groups on a four-point Likert scale. In order to establish face validity, two methods were used; the first one was a panel of experts who assessed the instrument based on three score criteria: clarity, accuracy and comprehension. They found that the instrument achieved these criteria in 96%, that is to say, in 45 out of 47 items. The second method was done by five study subjects who assessed the instrument as a whole for determining its comprehension. Thus, it was established that the instrument seems to have face validity. To establish the instrument's rehability level, it was applied to a 417 people sampling randomly chosen, who were older than 50 years, with untouched mental function, coming from the municipality of Chía and the city of Bogotá, between August 2005 and March 2006. Confidence level was evaluated through internal consistency with a Cronbach's Alpha of 0.88, stability was assessed using the Spearman's rank correlation coefficient (r = 0.94) for the whole instrument and a probabilistic ANOV A value statistically non significant (p = NS), which confirms the stability of the scores obtained through time.}, publisher = {Aquichan}, keywords = {Enfermos -- Atención -- Medición}, keywords = {Pacientes -- Atención -- Medición}, keywords = {Cuidados a los enfermos -- Enfermería -- Medición}, title = {Validez y confiabilidad de la versión en español del instrumento "Escala de medición del proceso de afrontamiento y adaptación" de Callista Roy}, author = {Gutiérrez López, Carolina and Veloza Gómez, Mónica del Mar and Moreno Fergusson, María Elisa and Durán de Villalobos, María Mercedes and López de Mesa Melo, Clara Beatriz and Crespo, Osvaldo}, }